Technical Resources
Machine Tool Pump Failures: Causes and Solutions
Author: WeidoyaPublished: 2025-12-29 09:24:38Views: 0
Fault causes and corrective actions.
| Symptom | Cause | Corrective action | |
|---|---|---|---|
| Unable to rotate. | When operating noise is present. | - Poor switch contact. - Broken wire. - Bearing wear causes the motor rotor to Contacts the stator. | - Check wire connections. - Contact Weidoya for service. - Replace the bearing. |
| When no operating noise is present. | - Open circuit in the motor winding. - Broken wire. - Poor switch contact. | - Contact Weidoya for service. - Repair the wiring. - Replace and adjust the switch. | |
| When rotating. | Noise and overcurrent. Overheating occurs. | - The motor rotor contacts the stator. - The motor rotor and stator are unbalanced. - An open phase in the stator winding. - Reverse rotation. | - Contact Weidoya for service. - Swap two of the three power leads. |
| Reduced discharge volume. | Low discharge volume. | - Insufficient oil in the tank. - Impeller wear. - Low oil viscosity. | - Eliminate the cause of air bubbles. - Replace the impeller. - Maintain appropriate viscosity (150 cSt at 30°C). |
| Discharge decreases sharply. | - The suction side is blocked by foreign matter. - Insufficient oil in the tank. | - Clean the suction inlet. - Refill oil. | |
Related Tags:
- Previous: Comparing A-RYUNG Coolant Pump Types: Selection Criteria
- Next: Weidoya Recommendations for Using Machine Tool Pumps
Latest News
- 2026-09-22 11:27:52
Recommended: Kytola SLM Smart Seal Water Flow Meter with 4–20 mA Output
- 2026-09-22 11:24:14
Variable area flow meters with 4-20 mA signal
- 2026-09-22 11:17:50
Let’s make your flow measurement Kytola Smart
- 2026-08-05 11:08:59
Kytola Gas Flow Conversion Formula
- 2026-08-05 11:03:07
Flow Meter Accuracy — Kytola, Finland
- 2026-08-05 11:01:20
How to Read a Kytola Variable Area Flow Meter