ARD-340,350 A-RYUNG · Korea

ARD-340,350 A-RYUNG · Korea

ARD-340 and ARD-350 metering valves are designed for indirect lubrication systems. A piston meters and supplies the required quantity of lubricating oil.

A small flow tolerance makes it suitable for precision lubrication systems.


Inquiry

 ARD  -  35     3  -  335
                      ①        ②          ③

① Type
    34 : 340 series
    35 : 350 series
② Number of distribution ports
     2, 3, 5
③ Flow rate code

 

√ ARD-340 and ARD-350 metering valves are designed for indirect lubrication systems. A piston meters and supplies the required quantity of lubricating oil.

A small flow tolerance makes it suitable for precision lubrication systems.

 

ModelDistribution port.Operating Pressure
MPa
Bore of pipeWeight
g
CodeDischarge Flow
cc/min
Main line.Branch line.
ARD-34220.8 ~ 3.0M10×1.0pM8×1.0p11510.03
ARD-34330.8 ~ 3.0M10×1.0pM8×1.0p16320.06
ARD-34550.8 ~ 3.0M10×1.0pM8×1.0p24930.10
ARD-35220.8 ~ 3.0M10×1.0pM8×1.0p23930.1
ARD-35330.8 ~ 3.0M10×1.0pM8×1.0p31450.2
ARD-35550.8 ~ 3.0M10×1.0pM8×1.0p46470.6

Operating mechanism.

Oil destined for the lubrication point is located ahead of the distributor piston.

 

When the controlled lubrication pump starts supplying oil, the piston moves and the oil ahead of it is delivered to the lubrication point under main-line pressure of 8–30 bar.

 

When main-line pressure is released, the distributor piston returns to its initial position, allowing oil into the space ahead of it.

 

Outline Drawing

 

ARD-340 Series

TypeABCDN
3424824-171
3436532.517342
3459949.551682

 

 

ARD-350 Series

 

TypeABD
3424522.517
343623134
3459547.568

 

 

Examples

 

ARD-340 Series

 

ARD-350 Series

 

For ARD-340 models with five outlet positions, refer to the table below when ordering.

Discharge Flow
cc/st
0.060.060.100.030.03
Order code22311
Order No.ARD-345-22311