AMGP-01A(F) A-RYUNG · Korea

AMGP-01A(F) A-RYUNG · Korea

The push-button digital counter built into AMGP-01A series lubrication pumps enables intermittent fluid delivery. AMGP-01A(F) is used with DB-type proportional distribution valves. AMGP-01AF-T is used with ARD-340, ARD-350 and PVO metering valves. Numbers and text on the front control panel make the digital controller easy to read and help identify abnormal pump conditions.

Inquiry

 AMGP  -  01A   F  -  T03  -  T  -  110
      ①                   ②        ③         ④          ⑤          ⑥ 

 

① ARYUNG Motor Gear pump
② Pump Type
③ Level Gauge
No mark: none; F: built-in
④ Tank Capacity (L)
     No mark : 1.8ℓ,  T03 : 3.0ℓ

⑤ Lubrication Method
No mark: proportional
T: metered
⑥ Voltage (V)

 

√ The push-button digital counter built into AMGP-01A series lubrication pumps enables intermittent fluid delivery.
AMGP-01A(F) is used with DB-type proportional distribution valves. AMGP-01AF-T is used with ARD-340, ARD-350 and PVO metering valves.

√ Numbers and text on the front control panel make the digital controller easy to read and help identify abnormal pump conditions.

√ Interval and discharge times are set conveniently and accurately, supplying the required quantity of lubricant.

√ An optional low-level alarm can be connected to an external controller.

√ The front FEED button makes it easy to purge air from piping and allows manual oil delivery.

√ Suitable for machine tools, printing, food processing, textile and injection molding equipment and other industrial machinery.

 

PUMP SPEC’

ModelDischarge Flow
cc/min
Operating Pressure
MPa
Pressure Range
MPa
Tank Capacity
ℓ
Operating Viscosity
cSt
Discharge Port
PT
Weight
kg 
Phase 1Ø, Poles 2P
Motor Power
W
Frequency
Hz
Voltage
V
Current
A
01A 
01AF
 850.8 0.2 ~ 1.7 1.8 30 ~ 220 1.8"(Ø4) 2.81550100/200 1.4/0.7
 10060 110/220 1.2/0.6
01AF-T 851.7 0.2 ~ 1.7 1.8 30 ~ 220 2.81550100/200 1.4/0.7
 10060 110/220 1.2/0.6
01AF-T03 1250.8 0.2 ~ 2.03.0 30 ~ 220 4.72550100/200 2.0/1.0
15060 110/220 1.8/0.9
01AF-T03-T 1251.7 0.2 ~ 2.03.0 30 ~ 220 4.72550100/200 2.0/1.0
15060 110/220 1.8/0.9

 

Circuit Diagram

 

AMGP-01A(F), 01AF-T03 — Proportional TypeAMGP-01AF-T, 01AF-T03-T — Metered Type



Wiring Diagram



①② : POWER
 ※  1 : RED
      2 : BLACK

 FLOAT S/W OPTION
 ①② : POWER
 ③④ : OIL ALARM
 ※  1 : RED     
      2 : BLACK
      3 : WHITE 
      4 : GREE

Panel description


 ①  Feed button
 ②  Reset button
 ③  Mode button
 ④  Interval FND
 ⑤  Discharge FND

Time Setting Procedure

* Adjustment Range
Interval Time 1~99min
Discharge Time 1~99sec
* Discharge Flow Calculation
  01A(F):100cc/min = 1.67cc/sec
  01AF-T03 :150cc/min = 2.50cc/sec

1. Setting Procedure
MODE ■: start setting / move / confirm and exit; ▲: increase value; ▼: decrease value
A) Press button ③ MODE ■. The interval digits flash. Press button ① ▲ to increase the value or button ② ▼ to decrease it.
After setting the required interval, press button ③ MODE ■ again. The discharge time digits flash. Use ① ▲ and ② ▼ to adjust the value. Once the required discharge time is set, press ③ MODE ■ to exit.
B) If no value is entered for ten seconds during setup, the system treats setup as complete and automatically returns to operation.
C) Each press of ▲ or ▼ changes the value by one. Holding the button changes the value continuously.


2. RESET Function
Pressing RESET during operation restores the initially configured operating state.


3. FEED Button (Manual Lubrication)
Press FEED during operation. The panel displays FEED and liquid is discharged while the button is held, independently of the set time. This is useful for purging air from piping and electrically feeding oil.


4. Low Oil Alarm (Optional)
When the tank oil level is low, the panel displays oil and a buzzer sounds, making the low level easy to identify.

Minimum Time Setting Conditions

Discharge TimeIntermittent Stop Time
1 ~ 10sec About 2min or more
11 ~ 30sec About 3min or more
31 ~ 60sec About 5min or more
61 ~ 99sec About 10min or more

 

Operating Time Settings

The pump generates heat during operation. Set the interval according to the table. If the interval is too short relative to discharge time, excessive motor temperature is detected by the internal safety device,which stops the motor automatically. Operation resumes after the temperature falls.

Outline Drawing

AMGP-01A(F), 01AF-T

 

 

 

 AMGP-01AF-T03, 01AF-T03-T

Applications

· Fluid:Oils
· Recommended Fluid:Winter: 32 cSt or lower
Summer: 68 cSt or lower
· Materials
Control box and cover: plastic
Tank: plastic
Gear pump: steel
Shaft: plastic / ZnDC
· Operating Temperature:Below 80°C
· Lubrication Method
Proportional: AMGP-01A, 01AF, 01AF-T03
Metered: AMGP-01AF-T, 01AF-T03-T
· Control Method: Digital type 
· Stop Time: 1~99min
· Discharge Time: 1~99sec
· Pressure Gauge:PG-35K (AMGP-01AF-T03) 
· Level Sensor:FS-A (optional)
· Fuse:0.3A

 