ACP-F Single-stage Immersion Pumps
ACP-F single-stage immersion pumps require no priming and use no mechanical shaft seal, avoiding failures caused by dry running. Their compact design suits a wide range of machine tools.
Immersion type.
ACP – F SERIES

① | ARYUNG Coolant pump |
② | Motor power (W). |
③ | Pump type. |
④ | Voltage: 2/2: 200/220 V; 2/3: 220/380 V; 4/4: 415/440 V. |
• ACP-F immersion pumps require no priming and use no mechanical shaft seal, avoiding failures caused by dry running. Their compact design suits a wide range of machine tools.
» PUMP SPEC |
| TYPE | P U M P | M O T O R | Weight (kg) | ||||||
| Discharge volume (ℓ/min) | Head (m) | Out-Let (PS) | Immersion depth (mm) | Out-put (W) | Frequency (Hz) | Voltage (V) | Current (A) | ||
| ACP-60F | 25 30 | 2 | 3/8" | 153 | 60 | 50 60 | 200/380/415 220/380/440 | 0.4/0.24/0.22 0.45/0.26/0.25 | 6.5 |
| ACP-100F | 35 45 | 2 | 3/8" | 158 | 100 | 50 60 | 200/380/415 220/380/440 | 0.5/0.29/0.27 0.55/0.32/0.31 | 7 |
| ACP-180F | 75 90 | 3 | 1/2" | 180 | 180 | 50 60 | 200/380/415 220/380/440 | 1/0.58/0.56 1.1/0.64/0.60 | 10.5 |
| ACP-250F | 120 150 | 4 | 3/4" | 258 | 250 | 50 60 | 200/380/415 220/380/440 | 1.5/0.87/0.82 1.6/0.93/0.88 | 14 |
| ACP-400F | 140 200 | 5 | 1" | 280 | 400 | 50 60 | 200/380/415 220/380/440 | 2.6/1.50/1.40 2.7/1.6/1.5 | 18.5 |
Protection rating • IP44 : ACP-60F, 100F, 180F, 250F
| Application • Fluid: | Material • Motor frame : ALDC |
The rated voltages shown in the table, 220V / 380V, are standard. Other voltage specifications can be manufactured; contact us for details.
» Performance curve (water-soluble cutting oil). |

» Performance curve (non-water-soluble cutting oil). |

» Appearance. |

| TYPE | L | L1 | L2 | L3 | TL | ØR1 | ØR2 | ØLA | ØLB | PE |
| ACP-60F | 153 | 19 | 100 | 20 | 316 | 90 | 90 | 132(130) | 130(130) | PS 3/8” |
| ACP-100F | 158 | 19 | 100 | 20 | 320 | 90 | 90 | 132(130) | 134(130) | PS 3/8” |
| ACP-180F | 180 | 20 | 118 | 25 | 365 | 115 | 115 | 160(160) | 134(160) | PS 1/2” |
| ACP-250F | 258 | 25 | 190 | 25 | 456 | 134 | 134 | 160(160) | 170(160) | PS 3/4” |
| ACP-400F | 280 | 28 | 200 | 65 | 515 | 135 | 135 | 180(180) | - | PS 1” |
Dimensions in parentheses for ØLA and ØLB in the table are specifications used in Korea.
- Previous: None
- Next: A-RYUNG · Korea Coolant Pumps ACP-100F
Related Products

A-RYUNG · Korea ACP-EF Single-stage Immersion Pumps

A-RYUNG · Korea Coolant Pumps ACP-180F

A-RYUNG · Korea Coolant Pumps ACP-100F

ACP-F Single-stage Immersion Pumps
Related Services / service
Regional Products / city
- Anhui — ACP-F Single-stage Immersion Pumps
- Beijing — ACP-F Single-stage Immersion Pumps
- Chongqing — ACP-F Single-stage Immersion Pumps
- Fujian — ACP-F Single-stage Immersion Pumps
- Gansu — ACP-F Single-stage Immersion Pumps
- Guangdong — ACP-F Single-stage Immersion Pumps
- Guangxi — ACP-F Single-stage Immersion Pumps
- Guizhou — ACP-F Single-stage Immersion Pumps
- Hainan — ACP-F Single-stage Immersion Pumps
- Hebei — ACP-F Single-stage Immersion Pumps