Installation Precautions for A-RYUNG Self-priming Pumps
A-RYUNG ACP-A self-priming pumps must be primed before first use after installation and before restarting after a long shutdown. Running without priming damages the mechanical seal. Do not run dry for 30 seconds or longer.
Fill with oil through the discharge port until all air in the pump has escaped through the suction port. Running the pump before it is completely filled can damage the seal; take care to prime it fully.
If the suction-line piping is lower than the discharge port, oil cannot be filled. Use another device to expel the air or raise the filling port.
The maximum suction length for a self-priming pump must be less than 0.6 m.
If the suction-pipe end is too close to the tank floor or wall, water hammer, noise and vibration may occur. Chips or other contaminants can reduce pump performance. Maintain sufficient clearance, at least 20–30mm.
Machining chips entering the pump can wear and damage the mechanical seal. Installing a filtration system is therefore recommended.

Korean A-RYUNG self-priming pump models:
ACP-61A
ACP-101A
ACP-181A
ACP-251A
ACP-401A
ACP-1101A (imported from Korea).
- Previous: Installation Precautions for A-RYUNG Immersion Pumps
- Next: A-RYUNG Notice of Changes to Energy Efficiency Labels
Latest News
- 2026-09-22 11:27:52
Recommended: Kytola SLM Smart Seal Water Flow Meter with 4–20 mA Output
- 2026-09-22 11:24:14
Variable area flow meters with 4-20 mA signal
- 2026-09-22 11:17:50
Let’s make your flow measurement Kytola Smart
- 2026-08-05 11:08:59
Kytola Gas Flow Conversion Formula
- 2026-08-05 11:03:07
Flow Meter Accuracy — Kytola, Finland
- 2026-08-05 11:01:20
How to Read a Kytola Variable Area Flow Meter