Welcome to Suzhou Weidoya — Industrial Lubrication, Cooling & Instrumentation

20 Years of Specialist Sales & Technical Experience

A-RYUNG · KYTOLA · Autonics · CHEN YING · Sensorik Austria

Specialist provider of lubrication and cooling systems

International Sales

+86 153 6620 7892
Home / Products / CHEN YING Lubricators · Taiwan, China / Resistance-type Grease Lubricators / Electric PLC-controlled Series
KGC Resistance-type Electric Grease Lubricator

KGC Resistance-type Electric Grease Lubricator

Non-metered lubrication.

PLC-controlled.


Inquiry

1. Operation and interval times are PLC-controlled.

2. Includes a pressure gauge for checking operating pressure.

3. Single-phase 110V, single-phase 220V and DC24V models include a manual lubrication button. Do not hold it down for more than 3 minutes, to prevent motor overload.

4. Single-phase 110V and single-phase 220V models include motor thermal protection. At 100°C, the motor temporarily stops for approximately 5 minutes.

5. An optional 60 kgf/cm² pressure switch can detect damage to the lubrication lines.

6. An optional reed-switch oil-level detector can monitor level and send a signal automatically.

7. Fill the KGC and KGCP-50 reservoirs through the grease nipple to prevent air and foreign matter from entering.

8. KGCP-07 must be used with a 700 cc bellows-type grease cartridge. Replace the empty cartridge without time-consuming refilling. Cartridges are sold separately; refer to the bellows-type grease cartridge ordering codes.

9. Refer to the diaphragm pressure switch specifications for contact information.

kgc — Dimensional drawing


◆ Dimensions

ModelEffective CapacityLength L (mm)Width W (mm)Height H (mm)Mounting hole pitch F (mm)Weight (kg)
KGC-351000cc1911462921044.07
KGC-502000cc1981513764.55



◆ Specifications.

Motor Output Power60W80W60W
VoltageSingle-phase 110 VSingle-phase 220 VDC24V
Current1.8A1A1.65A
Forced-feed ButtonOOO
Motor thermal protection device.OOX
FrequencyCompatible with 50 Hz and 60 Hz--
Maximum Discharge Rate30cc/min35cc/min
Maximum Discharge Pressure100kgf/c㎡
Oil Outlet SizeØ6, Ø8, PT1/8
Reed-type Oil Level SensorOptional (NC or NO contact)
Pressure SwitchOptional (NC or NO contact)
Applicable Oil ViscosityNLGI 000~0


Note: Reed-type level sensor contacts — NO signals when lubricant is present; NC signals when lubricant is absent.


◆ Wiring Diagram

kgc.kgcp-single-phase-power  — Wiring diagram
M: motor.
DK: forced lubrication button.
GND: Ground
Power
Connect PLC: connection to PLC.

※ For AC power, 0 V and 24 V polarity need not be observed during wiring.




◆ Ordering code.

ModelReservoir capacity.VoltageOil Outlet SizeSpecial Requirements
KGC35C3※

351000ccASingle-phase 110 V1Ø6PCAdditional pressure switch, NC contact

502000ccCSingle-phase 220 V3Ø6 (with pressure gauge)POAdditional pressure switch, NO contact



KDC24V4Ø8RCAdditional reed-type oil level sensor, NC contact





5Ø8 (with pressure gauge)ROAdditional reed-type oil level sensor, NO contact





6PT1/8






7PT1/8 (with pressure gauge)

Recommended Compatible Products

11111.png2222.png

Related Products

WhatsApp