CESS/CESSB Resistance-type Electric Lubricators
Adjustable discharge volume
Fixed interval time
1. A small synchronous motor drives the CES lubricator’s worm and worm wheel. A fixed interval provides automatic, timed and metered oil delivery without an external controller or timer.
2. The discharge volume of CES-series lubricators is adjustable.
3. CESMB and CESSB include a normally open float switch that continuously sends a signal when the oil level is above the minimum.
4. CESC includes a normally closed float switch that continuously sends a signal when oil level falls below the minimum.
5. The CESC electronic box has three indicators: POWER, ACTION and ALM (alarm).
6. CESMA and CESMB can be fitted with a power indicator that lights when power is on.
7. CESSB can be fitted with a CE connector to change from a lead-out cable to a sealed connection.
8. Refer to the float / float switch specifications for contact information.
◆ Dimensions and Model Equipment Table (O: included; ☆: optional; X: not applicable.)
| Model | Tank Capacity | Length L (mm) | Width W (mm) | Height H (mm) | Mounting hole pitch F (mm) | Weight (kg) | Float Switch | Buzzers | Pressure gauge | Electronic control box. | Indicator light. | Wiring method. |
| CESS | 1L | 129 | 91 | 200 | 100 | 1.28 | X | X | X | X | X | Lead-out cable type. CESSB can be fitted with a CE connector for a sealed connection. |
| CESSB | 159 | 91 | 200 | 100 | 1.30 | O | X | X | X | X |
◆ Specifications.
| Interval time | 2, 3, 5, 10, 15, 30 or 60 minutes (one setting selected at the factory; not user-adjustable) | |
| Motor output power. | 4W | |
| Voltage | 110V | 220V |
| Current | 0.1A | 0.05A |
| Frequency | Compatible with 50 Hz and 60 Hz | |
| Maximum Discharge Rate | 3 cc; 1–3 cc is also available. | |
| Maximum discharge pressure. | 3kgf/c㎡ | |
| Oil outlet size. | Ø4 , Ø6 | |
| Float switch. | CESSB: NO contact (can be changed to NC). | |
| Applicable oil viscosity. | 32–68 cSt at 40°C. Contact customer service about special oil viscosities. | |
◆ Wiring Diagram
◆ Ordering code.
| Model | Interval time | Voltage | Discharge Volume | Oil outlet size. | Special Requirements | |||||
| CESS | 10 | C | 3 | 1 | ※ | |||||
| CESSB | 02 | 2 minutes | A | 110V | 1 | 1–3 cc (adjustable). | 0 | Ø4 | H | Add a CE connector (CESSB only). |
| 03 | 3 min | C | 220V | 3 | 3 cc (not adjustable). | 1 | Ø6 | SC | Change the float switch to an NC contact (CESSB only). | |
| 05 | 5 min | |||||||||
| 10 | 10 min | |||||||||
| 15 | 15 minutes. | |||||||||
| 30 | 30 minutes. | |||||||||
| 60 | 60 minutes. | |||||||||



- Previous: None
- Next: CESC Resistance-type Electric Lubricator
Related Products

CESMA Resistance-type Electric Lubricator

CESMB Resistance-type Electric Lubricator

CESC Resistance-type Electric Lubricator

CESS/CESSB Resistance-type Electric Lubricators
Related Services / service
Regional Products / city
- Anhui — CESS/CESSB Resistance-type Electric Lubricators
- Beijing — CESS/CESSB Resistance-type Electric Lubricators
- Chongqing — CESS/CESSB Resistance-type Electric Lubricators
- Fujian — CESS/CESSB Resistance-type Electric Lubricators
- Gansu — CESS/CESSB Resistance-type Electric Lubricators
- Guangdong — CESS/CESSB Resistance-type Electric Lubricators
- Guangxi — CESS/CESSB Resistance-type Electric Lubricators
- Guizhou — CESS/CESSB Resistance-type Electric Lubricators
- Hainan — CESS/CESSB Resistance-type Electric Lubricators
- Hebei — CESS/CESSB Resistance-type Electric Lubricators




