Welcome to Suzhou Weidoya — Industrial Lubrication, Cooling & Instrumentation

20 Years of Specialist Sales & Technical Experience

A-RYUNG · KYTOLA · Autonics · CHEN YING · Sensorik Austria

Specialist provider of lubrication and cooling systems

International Sales

+86 153 6620 7892
Home / Products / A-RYUNG · Korea / Lubrication Pumps / Auto Type
AMGP-013(F),015(F) A-RYUNG · Korea

AMGP-013(F),015(F) A-RYUNG · Korea

The built-in analog timer enables intermittent oil delivery and is used with proportional distribution valves. The vibration-resistant construction provides durability even on machines with severe vibration.

Inquiry

 AMGP  -  013   F  -  110
     ①                    ②       ③          ④ 

 

① ARYUNG Motor Gear pump
② Pump Type
③ Level Gauge
No mark: none; F: built-in
④
Voltage (V)

 

√ The built-in analog timer enables intermittent oil delivery and is used with proportional distribution valves.

√ The vibration-resistant construction provides durability even on machines with severe vibration.

√ An optional low-level alarm can be connected to an external controller.

√ The front FEED button makes it easy to purge air from piping and allows manual oil delivery.

√ Suitable for machine tools, printing, food processing, textile and injection molding equipment and other industrial machinery.

 

PUMP SPEC’

ModelDischarge Flow
cc
Stop Time
Min
Operating Pressure
MPa
Tank Capacity
ℓ
Operating Viscosity
cSt
Discharge Port
PT
Weight
kg 
Phase 1Ø, Poles 2P
Motor Power
W
Frequency
Hz
Voltage
V
Current
A
013
013F
5 ~ 1003 ~ 30 0.8 1.8 30 ~ 2201/8"(Ø4) 2.81550100/200 1.4/0.7
60 110/220 1.2/0.6
015
015F
5 ~ 803 ~ 120 0.8 1.8 30 ~ 2201/8"(Ø4) 2.81550100/200 1.4/0.7
60 110/220 1.2/0.6

 

Circuit Diagram

AMGP-013(F), 015(F) — Proportional Type



Wiring Diagram



①② : POWER
 ※  1 : RED      2 : BLACK


 FLOAT S/W OPTION
 ①② : POWER
 ③④ : OIL ALARM
 ※ 1 : BLACK 2 : RED
     3 : GREEN 4 : WHITE



Minimum Time Setting Conditions

Discharge TimeIntermittent Stop Time
1 ~ 10secAbout 2min or more
11 ~ 30secAbout 3min or more
31 ~ 60secAbout 5min or more
61 ~ 99secAbout 10min or more

The pump generates heat during operation. Set intervals according to the table. If the interval is too short relative to discharge time, the internal safety device detects excessive motor temperature and stops the motor automatically. Operation resumes after cooling.

Outline Drawing

AMGP-013/015

 

AMGP-013/015F

 

Applications

· Fluid:Oils
· Recommended Fluid:Winter: 32 cSt or lower
Summer: 68 cSt or lower
· Materials
Control box: plastic
Cover: plastic
Tank: plastic
Gear pump: steel
Shaft: plastic / ZnDC
· Operating Temperature:Below 80°C
· Lubrication Method:Proportional Type
· Control Method: Analog type
· Level Sensor:FS-A (optional)
· Fuse:0.3A


Related Products