ACFS Series A-RYUNG · Korea
A separate platform structure simplifies maintenance and management.
An air-based cleaning system allows the filter to be reused, extending replacement intervals and reducing the work and maintenance costs associated with filter replacement.
ACFS - T216 - 30 - C15 - E50
① ② ③ ④ ⑤
① ARYUNG Coolant Filter Structure
② Pump Type
T216 : ATP-216
T212 : ATP-212
③ Pressure
20 : 20bar
30 : 30bar
④ Primary Filtration Specification
Cyclone filter
C15 : ARCF-15B
C20 : ARCF-20B
C25 : ARCF-25B
⑤ Secondary filtration specification (case size: 6”)
Element Filter : E140 : 140㎛
Bag Filter(Option) : B25 : 25㎛
B50 : 50㎛
Product Features
• Separate tabletop type.
•Pump used: ATP-216CH (maximum 29 L/min).
- ATP-212CH (Max’ 21L/min)
•Maximum operating pressure: 20 bar / 30 bar.
•Uses dual filters.
First-stage filtration: cyclone filter.
Second-stage filtration: element filter or bag filter.
•Provides secondary filtration and cleaning. An air cleaning system cleans the filter without disassembly, allowing reuse and longer replacement intervals while reducing replacement work and maintenance costs.
•Built-in supply-pump pressure gauge: 1–3.5bar
•Built-in pump-integrated pressure-regulating valve: 5–40 bar adjustment range.
Product Specifications
| Model Name | ACFC-T216-20 | ACFC-T212-30 | ||
| Motor Power | 1.5kW | 1.5kW | ||
| Phase / Poles | 3Ø / 4P | 3Ø / 4P | ||
| Frequency [Hz] | 50 | 60 | 50 | 60 |
| Voltage [V] | 200 / 380 | 220 / 380 | 200 / 380 | 220 / 380 |
| Current [A] | 6.3 / 3.6 | 6.1 / 3.5 | 6.3 / 3.6 | 6.1 / 3.5 |
| Max. Flow rate [ℓ/min] | 24 | 29 | 18 | 21.6 |
| Max. Pressure | 20bar / 2.0MPa | 30bar / 3.0MPa | ||
| Standard test Nozzle | Ø2.0 | |||
| Relief valve (Pressure Range) | 5 ~ 50 bar | |||
| Cyclone filter (first stage). | ARCF-15B, 20B,25B | |||
| Second-stage filter element: standard. | E140 : 140㎛ (100mesh) | |||
| Bag filter (2차) Option | 25㎛, 50㎛ | |||
| Supply In-let | Rc 1" or 3/4" | |||
| Discharge Out-let | Rc 3/4" | |||
| Drain | Rc 1" | |||
| Control method | External control | |||
| Supply Pressure S/W | Option | |||
| Discharge Pressure S/W | Option | |||
| Noise [ dB(A) ] | 75 under | |||
Circuit Diagram

| No. | Part name. |
| 1 | High pressure pump |
| 2 | Relief Valve |
| 3 | Cyclone filter |
| 4 | Pressure gauge (Supply pressure) |
| 5 | Element filter or Bag filter |
| 6 | Ball valve (B) |
| 7 | Ball valve (A) |
Second-stage filter cleaning instructions (element or bag filter).
Close ball valve No. 7 (A), then slowly open ball valve No. 6 (B) to clean the filter. After cleaning, close valve No. 6 (B) and fully open valve No. 7 (A).
Dimensional Drawing

Related Products
Related Services / service
Regional Products / city
- Anhui — ACFS Series A-RYUNG · Korea
- Beijing — ACFS Series A-RYUNG · Korea
- Chongqing — ACFS Series A-RYUNG · Korea
- Fujian — ACFS Series A-RYUNG · Korea
- Gansu — ACFS Series A-RYUNG · Korea
- Guangdong — ACFS Series A-RYUNG · Korea
- Guangxi — ACFS Series A-RYUNG · Korea
- Guizhou — ACFS Series A-RYUNG · Korea
- Hainan — ACFS Series A-RYUNG · Korea
- Hebei — ACFS Series A-RYUNG · Korea