ACFO Series A-RYUNG · Korea
Open design for easy maintenance Cutting oil containing particles separated by the cyclone filter flows naturally into the drain.
ACFO - G17 - 20 - C15 - E70
① ② ③ ④ ⑤
① ARYUNG Coolant Filter Open type system
② Pump Type
Gear Pump : G17
Screw Pump : S20
③ Pressure
G17 ⇒ 20 : 20bar, 30 : 30bar, 50 : 50bar
S20 ⇒ 30 : 30bar
④ Primary Filtration Specification
Cyclone filter
C15 : ARCF-15B
C20 : ARCF-20B
C25 : ARCF-25B
⑤ Secondary Filtration Specification
E140 : Element filt er-140㎛
B25 : Bag filter-25㎛
B50 : Bag filter-50㎛ (Option)
I Product Features
• Open design for easy maintenance
• High-pressure pump
Gear pump : G17 series
Screw pump : S20 Series
• Dual-filter configuration
Primary filter: cyclone filter
Primary cyclone filtration performance depends on the cutting material. Typically, approximately 95% or more of particles of about 10 μm–2 mm can be recovered without replacement, allowing long-term use.
Secondary filter: element filter or bag filter
The secondary element or bag filter removes suspended material and particles not captured by the cyclone filter for thorough filtration.
• Cutting oil containing particles separated by the cyclone filter flows naturally into the drain.
• Built-in discharge pressure gauge: 60 / 100 bar
• Optional discharge pressure switch: 5 bar
Detects high-pressure pump operation
• Built-in supply pump pressure gauge: 1–3.5 bar
• Built-in secondary pressure gauge: 0.8 bar indicates cleaning is required
• Optional supply pressure switch: 1 bar
• Built-in float switches: high and low level
• Built-in pressure regulating valve: adjustment range 5–70 bar
• Optional casters for moving and installation
I Product Specifications
| Model Name | ACFO-G17-20 | ACFO-G17-30 | ACFO-G17-50 | ACFO-S20-30 |
| Motor Power | 1.5kW/4P | 2.2kW/4P | 4.0kW/4P | 3.0kW/2P |
| Voltage(V) | 30, 220/380, 50/60Hz | |||
| Max. Pressure | 20bar/2.0MPa | 30bar/3.0MPa | 50bar/5.0MPa | 30bar/3.0MPa |
| Max. Flow rate [50/60Hz] | 23.0/28.0(l/min) | 23.0/28.0(l/min) | 23.0/28.0(l/min) | 27.0/34.0(l/min) |
| Standard test Nozzle | Ø2.0(5.8l/min) | Ø2.0(5.8l/min) | Ø2.0(10.0l/min) | Ø2.0(10.0l/min) |
| Clean Tank | Single : 36l / Dual : 65l | Single : 36l, 140l Dual : 65l | ||
| Relief valve (Pressure Range) | 5~70bar | |||
| Cyclone Filter (1st) | Built in | |||
| Element (2nd) - Standard | 50μm, 70μm | 50μm, 70μm / - | ||
| Bag filter (2nd) - Option | 25μm, 50μm | 25μm, 50μm / - | ||
| Supply In-let | Rc 3/4" | Rc 3/4" / Rc 1" | ||
| Discharge Out-let | Rc 1/2" x JIS 1/2" | Rc 1/2" x JIS 1/2" / Rc3/4" | ||
| Drain / Dirty Drain | Rc 1" / Rc 3/4" | Rc 1" / Rc 3/4" | ||
| Over Flow | Rc 1 1/4" | Rc 1 1/4" / 2" | ||
| Control Method | External control | |||
| Supply Pressure Sensor | Option | |||
| Discharge Pressure Sensor | Option | |||
| Noise [dB(A)] | 80 under | 75 under | ||
I Recommended Supply Pump Specifications
Single
| Model Name | ACP-1100HMFS 45 | |
| Frequency | 50 Hz | 60 Hz |
| Power Source | 200V / 380V | 220V / 380V |
| Current | 4.4A / 2.5A | 4.8A / 2.8A |
| Discharge Volume | 55ℓ/min | 60ℓ/min |
| Head | 20m | 25 m |
| Out - let | Rc 3/4" | |
Dual
| Model Name | ACP-1800 MF(S) | |
| Frequency | 50 Hz | 60 Hz |
| Power Source | 200V / 380V | 220V / 380V |
| Current | 6.6A / 3.8A | 7.2A / 4.2A |
| Discharge Volume | 100 ℓ/min | 150 ℓ/min |
| Head | 20m | 25 m |
| Out - let | Rc 1 1/4” | |
I Motor Specifications
| Out-put [ Kw ] | Frequency [ Hz ] | Poles [ P ] | Voltage | Current [ A ] |
| 1.5 | 50 | 4 | 200 / 380 | 6.3 / 3.6 |
| 60 | 220 / 380 | 6.1 / 3.5 | ||
| 2.2 | 50 | 4 | 200 / 380 | 8.8 / 5.1 |
| 60 | 220 / 380 | 8.3 / 4.8 | ||
| 4.0 | 50 | 4 | 200 / 380 | 15.2 / 8.8 |
| 60 | 220 / 380 | 14.5 / 8.4 | ||
| 3.0 | 50 | 2 | 200 / 380 | 12.5 / 7.2 |
| 60 | 220 / 380 | 11.0 / 6.4 |
I Pressure / Float Switches (Optional)
| Discharge Pressure S/W | 0.5MPa | AC250V 1.7A DC32V 1.7A |
| Supply Pressure S/W | 0.1MPa | AC250V 1.7A DC32V 1.7A |
| Float S/W (Clean Tank) | High /Low Level | AC250V 0.33A DC200V 0.5A |
I Main Component Description

Back

Front
I Circuit Diagram
Single 1

| No. | Component Names |
| 1 | High pressure pump |
| 2 | 1st Cyclone filter |
| 3 | 2nd Filter (Element or Bag) |
| 4 | Pressure Gauge (Supply Inlet) |
| 5 | Pressure Gauge (2nd Filter) |
Dual

| No. | Component Names |
| 6 | Relief Valve |
| 7 | Pressure Switch |
| 8 | Pressure Gauge (High Pressure) |
| 9 | Float Switch |
| 10 | Fluid Level Gauge |
| 11 | Control Box |
Single 2

| No. | Component Names |
| 1 | SCREW PUMP |
| 2 | MOTOR |
| 3 | CYCLONE FILTER |
| 4 | CLEAN TANK |
| 5 | PRESSURE GAUGE |
| 6 | FLUID LEVEL GAUGE |
| 7 | PRESSURE GAUGE |
| 8 | PRESSURE SWITCH |
| 9 | PRESSURE SWITCH |
| 10 | PROXIMITY SENSOR |
| 11 | MS CONNECTOR |
| 12 | CHIP BOX |
| 13 | CONTROL BOX |
Single

Dual


Note: Tank dimensions can be changed to meet customer requirements.
Related Products
Related Services / service
Regional Products / city
- Anhui — ACFO Series A-RYUNG · Korea
- Beijing — ACFO Series A-RYUNG · Korea
- Chongqing — ACFO Series A-RYUNG · Korea
- Fujian — ACFO Series A-RYUNG · Korea
- Gansu — ACFO Series A-RYUNG · Korea
- Guangdong — ACFO Series A-RYUNG · Korea
- Guangxi — ACFO Series A-RYUNG · Korea
- Guizhou — ACFO Series A-RYUNG · Korea
- Hainan — ACFO Series A-RYUNG · Korea
- Hebei — ACFO Series A-RYUNG · Korea