ACFC Series Open Separate Unit A-RYUNG · Korea
Open, separate-unit design for convenient maintenance Dual-filter configuration (FC type)
ACFC - T330 - 40 - C15 - B25
① ② ③ ④ ⑤
① ARYUNG Coolant Filter Structure
② Pump Type
T216CH : AMTP-3000-T216CHVD-H
T330CH : AMTP-4000-T330CH-V
③ Pressure
30 : 30bar, 40 : 40bar
④ Primary Filtration Specification
C15 : ARCF-15B, / C20 : ARCF-20B
⑤ Secondary Filtration Specification
B25 : BAG FILTER (25㎛) / B50 : BAG FILTER (50㎛)
• Open, separate-unit design for convenient maintenance
• High-pressure Pump
AMTP-3000-T216CHVD-H
AMTP-4000-T330CH-V
•Dual-filter configuration (FC type)
Primary filter: cyclone filter
Primary cyclone filtration performance depends on the cutting material. Typically, at least approximately 95% of foreign matter of about 10 μm–2 mm can be recovered. No replacement is required, allowing long-term use.
Secondary filter: bag filter
The secondary bag filter removes suspended material and other particles not captured by the cyclone filter for thorough filtration.
•Check pressure with a gauge or sensor to identify a clogged or abnormal bag filter. When pressure exceeds 1 bar, assess whether filter replacement is required.
Alternatively, a low-level float switch alarm in the clean tank can indicate filter clogging.
•Built-in discharge pressure gauge: 60 / 100 bar
• Optional discharge pressure switch: 5 bar
Detects whether the high-pressure pump is running
• Built-in supply pump pressure gauge: 1–3.5 bar
• Built-in float switch:
1. High / Middle level: supply on / off. 2. Low level: filter replacement
• Casters facilitate moving and installation
Product Specifications
| MODEL NAME | ACFC-T216-30-C15-B25 | ACFC-T330-30-C15-B25 | |
| MOTOR POWER | 3.0kW | 4.0kW | |
| VOLTAGE (V) | 3ø, 220/380 | ||
| FREQUENCY (Hz) | 50 | 60 | 50 |
| CURRENT (A) | 12.5/7.2 | 11.0/6.4 | 15.2/8.8 |
| Discharge Volume (ℓ/min) | 14.0 | 18.0 | 23.2 |
| PRESSURE | 30bar / 3.0MPa | 30bar / 3.0MPa | |
| STANDARD TEST NOZZLE | ø1.5 | ø3.0 | |
| CLEAN TANK | 120L | 130L | |
| CYCLONE FILTER | 15B (35ℓ/min), 20B (40ℓ/min) | ||
| BAG FILTER | 25㎛, 50㎛ | ||
| SUPPLY In-let | PT 3/4" | ||
| DISCHARGE Out-let | PT 1/2" | ||
| DRAIN / DIRTY DRAIN | 1" / 3/4" | ||
| OVER FLOW | 1" | ||
| Control Method | External Control | ||
| Supply pressure sensor | Option | ||
| Discharge pressure sensor | Option | ||
| NOISE [dB(A)] | 80 under | ||
Performance Curves
• Temperature: 40°C; viscosity: 32 cSt
• Orifice hole : 1ea
• Max’ pressure : 3.5MPa
AMTP-3000-T216CHVD (32cSt)

• Temperature: 40°C; viscosity: 32 cSt
• Orifice hole : 1ea
• Max’ pressure : 3.5MPa
AMTP-4000-T330CH (32cSt)

ACFC-T216-30-C15-B25 Dimensional Drawing

| NO. | Component Names |
| 1 | HIGH PRESSURE PUMP |
| 2 | BAG FILTER |
| 3 | TANK |
| 4 | FLOAT SWITCH (HIGH, MIDDLE) |
| 5 | FLOAT SWITCH (LOW) |
| 6 | CYCLONE FILTER |
ACFC-T330-30-C15-B25 Dimensional Drawing

| NO. | Component Names |
| 1 | HIGH PRESSURE PUMP |
| 2 | BAG FILTER |
| 3 | TANK |
| 4 | FLOAT SWITCH (HIGH, MIDDLE) |
| 5 | FLOAT SWITCH (LOW) |
| 6 | CYCLONE FILTER |
- Previous: None
- Next: ACFC Series Cabinet Separate Unit A-RYUNG · Korea
Related Products

ACFC Series Open Separate Unit A-RYUNG · Korea

ACFC Series Cabinet Separate Unit A-RYUNG · Korea

ACFC Series Cabinet Separate Unit A-RYUNG · Korea

ACFC Series Open Separate Unit A-RYUNG · Korea
Related Services / service
Regional Products / city
- Anhui — ACFC Series Open Separate Unit A-RYUNG · Korea
- Beijing — ACFC Series Open Separate Unit A-RYUNG · Korea
- Chongqing — ACFC Series Open Separate Unit A-RYUNG · Korea
- Fujian — ACFC Series Open Separate Unit A-RYUNG · Korea
- Gansu — ACFC Series Open Separate Unit A-RYUNG · Korea
- Guangdong — ACFC Series Open Separate Unit A-RYUNG · Korea
- Guangxi — ACFC Series Open Separate Unit A-RYUNG · Korea
- Guizhou — ACFC Series Open Separate Unit A-RYUNG · Korea
- Hainan — ACFC Series Open Separate Unit A-RYUNG · Korea
- Hebei — ACFC Series Open Separate Unit A-RYUNG · Korea